MaalonDrive® MedTec 10mm - Type 1

MaalonDrive®

MedTec 10mm - Type 1

Technical Supply Specifications

Features

  • Fast delivery
  • High repeatability
  • Zero backlash with high transmission ratio
  • Sterilizable
  • Preloaded ball bearing

Description

The MaalonDrive® MedTec 10mm - type 2 micro positioning gear was designed for use in medical technology and – for this reason – is characterised, in particular, by its outstanding sterilisability. The micro gearbox is equipped with preloaded ball bearings on both the input side as well as on the output side by means of which the customer application can be directly connected. At the heart of this high-reduction and zero-backlash micro gearbox is a MaalonDrive® gear with a reduction ratio of 500:1 in just a single stage.

Technical Parameter

Global System
Number Parameter Symbol Value Hint
P-002
Sterilizable yes  
P-003
Ratioi500 : 1 
P-004
Self-locking yes  
P-008
Repeatability unidirectional 15 arcsec 
P-009
Repeatability bidirectional 30 arcmin 
P-010
Accuracy 15 arcmin 
P-011
Transmission accuracy 30 arcmin 
P-013
Torsional stiffness 6.13 Nm/rad 
P-014
Lost motion 30 arcmin 
P-015
Backlash 0 arcmin 
P-016
Rated torqueT4 mNm 
P-017
Peak torqueT12 mNm 
P-018
Momentary peak torqueT16 mNm 
P-021
Rated input speedn10000 rpm 
P-022
Maximum input speedn30000 rpm 
P-023
Rated output speedn20 rpm 
P-024
Maximum output speedn20 rpm 
P-026
No-load starting torqueT225 μNm 
P-027
No-load running torqueT150 μNm 
P-028
Rated running torqueT1300 μNm 
P-034
Lifetime for rated operation 500 h 
P-035
Radial backlash output shaft 0 μm 
P-036
Axial backlash output shaft 0 μm 
P-037
Radial stiffnessc2.3 N/μm 
P-038
Axial stiffnessc40 N/μm 
P-039
Max. radial load on output shaft (non-operating, constant load)F55 N 
P-040
Max. radial load on output shaft (non-operating, impulsive load)F20 N 
P-041
Max. radial load on output shaft (operating, constant load)F7 N 
P-042
Max. radial load on output shaft (operating, impulsive load)F7 N 
P-043
Max. axial load on output shaft (non-operating, constantF150 N 
P-044
Max. axial load on output shaft (non-operating, impulsive load)F50 N 
P-045
Max. axial load on output shaft (operating, constant load)F380 N 
P-046
Max. axial load on output shaft (operating, impulsive load)F127 N 
P-047
Max. radial load on input shaft (non-operating, constant load)F20 N 
P-048
Max. radial load on input shaft (non-operating, impulsive load)F6 N 
P-049
Max. radial load on input shaft (operating, constant load)F5 N 
P-050
Max. radial load on input shaft (operating, impulsive load)F5 N 
P-051
Max. axial load on input shaft (non-operating, constant load)F64 N 
P-052
Max. axial load on input shaft (non-operating, impulsive load)F20 N 
P-053
Max. axial load on input shaft (operating, constant load)F185 N 
P-054
Max. axial load on input shaft (operating, impulsive load)F66 N 
P-055
Moment of inertiaI59 * 10-4 gcm2 
P-056
Weightm6 g 
P-057
Min. permissible ambient temperature (non-operating)T-80 °C 
P-058
Min. permissible ambient temperature (operating)T-10 °C 
P-059
Max. permissible ambient temperature (non-operating)T150 °C 
P-060
Max. permissible ambient temperature (operating)T120 °C 
Material information
Number Parameter Symbol Value Hint
P-900
RoHS compliant yes  
P-901Lubrication of output bearing gearbox BarriertaL55/2  
P-902Lubrication of input bearing gearbox BarriertaL55/2  
P-903Lubrication of gear component set BarriertaL55/2  
P-908Material of gear component set NiFe  
P-909Material of output bearing gearbox 1.4108 DIN EN  
P-910Material of input bearing gearbox 1.4108 DIN EN  
P-912Material of gearbox output side 1.4305 DIN EN  
P-913Material of gearbox input side 1.4305 DIN EN  
P-029 - Running torque characteristic

Technical Drawing

MaalonDrive® MedTec 10mm - Type 1